5.4 Electrical connections

Connect the appliance to a 230 V ~ 50 Hz
socket-outlet with earthing contact. Minimum
fuse 10 ampere.
A built-in thermostat protects the motor from
overloading and blocking. The pump is swit-
ched off automatically by the thermostat if
overheating occurs and is switched on again
automatically after cooling.
6. Operation
Install the equipment on a solid and level
surface.
The first time the filter is used, venting must
be performed at the ventilation screw (9)
while the pump is being filled.
Fill the pump housing with water via the water
filler screw (2). Filling the intake line will acce-
lerate the priming process.
All the shut-off devices in the discharge line
(spray nozzle, valves etc.) must be fully ope-
ned during intake in order to permit all air to
escape from the intake line.
Connect the mains cable.
Switch on the equipment with the power
switch – priming can take up to 5 minutes at
maximum suction height.
After finishing the work, switch off the equip-
ment with the power switch.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_NPGP_E_5500_SPK7.indb 15
Anl_NPGP_E_5500_SPK7.indb 15
GB
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, howe-
ver, we recommend that you regularly check and
care for the product.
Danger!
The equipment must be disconnected from the
power supply (pull the power plug) prior to perfor-
ming any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect
the discharge line to the water line and dis-
connect the suction hose. Open the water
line. Switch on the equipment several times
for approx. two seconds. This should resolve
the majority of clog-related problems.
There are no parts inside the equipment
which require additional maintenance.
8.2 Cleaning the fi lter element
Clean the filter element at regular intervals,
and replace it when necessary.
Release the filter housing (6) by turning it
counter-clockwise and remove the filter ele-
ment (7).
Do not use abrasive cleaning agents or petrol
to clean the filter element.
Clean the filter element by tapping it out on
a flat surface. In cases of stubborn dirt first
clean with soapy water, then rinse with clear
water and leave to dry in the air. Assemble in
reverse order.
When assembling the filter, make sure that
the sealing ring is inserted.

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
- 15 -
19.05.14 11:27
19.05.14 11:27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

41.822.42

Tabla de contenido