Procedure:
Step 1: Unscrew the fixation-screw of the protective grille.
Step 2: Remove the protective grille.
Step 3: Unscrew the fixation-screws of the colour-filter holder.
Step 4: Remove the colour-filter holder.
Step 5: If replacing a lamp, remove the old lamp from the lamp-socket.
Step 6: Put the eight ENH 120 V/250 W GY-5,3 lamps into the respective lampholders.
Step 7: Put the first two lamp-sockets on the first two lamps.
Step 8: Put the remaining lamp-sockets on the respective pair of lamps (connected in series).
Step 9: Replace the colour-filter holder and tighten the screws.
Step 10: Replace the protective grille and tighten the screw.
Step 11: For transport, replace the protection-cover and tighten the screw.
Overhead rigging
Please consider the DIN 15560 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and or
damage to property.
The device has to be installed out of the reach of people.
If the device shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The device must never be fixed swinging freely in the room.
Do not operate this device with opened colour-filter holder!
DANGER TO LIFE!
14/31
41907050X87NXS_V_1_0.DOC