Inversor RS Smart Solar
[en] While no further configuration is required on the , it is important that the AC PV inverter is configured correctly to respond to
the frequency adjustment by reducing its output.
[en] Note the 1:1 rule of AC PV inverter size to size, and minimum battery sizing applies. More information about these limitations
are available in the
AC Coupling
manual, and this document is required reading if using an AC PV inverter.
[en] The frequency adjustment range is not configurable, and includes a built in safety margin. Once the absorption voltage is
reached, the frequency will increase. So it is still essential to include a DC PV component in the system for complete battery
charging (i.e. float stage).
[en] It may be possible to adjust the power output response to various frequencies on your AC PV inverter.
[en] The default configuration has been tested and works reliably with the Fronius MG50/60 grid code configuration.
Página 14
Instalación