1.
Attach wheels with shoulder bolts
and nuts as shown.
2.
Tighten securely. NOTE: The unit
will sit level if the wheels are prop-
erly installed.
The wheels and
handle do not
provide adequate clearance, stability
or support for pulling the unit up and
down stairs or steps. The unit must
be lifted, or pushed up a ramp.
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
Locate the air compressor in a
clean, dry and well ventilated
area.
The air compressor should be
located at least 12" (30.5 cm)
away from the wall or other
obstructions that will interfere
with the flow of air.
Place the air compressor on a flat
level surface resting on the rub-
ber strip and wheels
The air compressor pump and
shroud are designed to allow for
proper cooling. The ventilation
openings on the compressor are
necessary to maintain proper
operating temperature. Do not
place rags or other containers on
or near these openings.
GROUNDING
INSTRUCTIONS
event of a short circuit, grounding
reduces the risk of shock by
providing an escape wire for
the electric current. This air
compressor must be properly
grounded.
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following illustra-
tions).
1.
The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.

INSTALLATION

Risk of Electrical
Shock. In the
Assemble Rubber Strip
1.
Clean and dry underside of air
tank leg opposite wheels.
2.
Remove the protective paper strip
from the adhesive backed rubber
foot strip.
3.
Attach the rubber foot strip to the
bottom of leg. Press firmly into
place.
IMPORTANT: The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
2.
Make sure the outlet being used
has the same configuration as the
grounded plug. DO NOT USE AN
ADAPTER. See illustration.
Plug
Grounding Pin
3.
Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
4.
If these grounding instructions are
not completely understood, or if in
doubt as to whether the compres-
sor is properly grounded, have the
installation checked by a qualified
electrician.
GROUNDING CAN RESULT IN
ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed by
a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified
electrician.
11 - ENG
Grounded
Outlets
Risk of Electrical
Shock. IMPROPER
1000002921