Warning: before closing the tool head release the oil pressure and retract the lower blade, oth-
erwise the head may hit and damage the lower blade.
4.1.2) Upper blade
– Release latch (16) and open the tool head.
– Remove the circlip (23) and extract the head pivot (24).
– Remove circlip (14) and latch pivot (13), to release the latch (16). Remove latch spring (12) from
the spacer (09).
– Using a 10 mm spanner, remove 8 nuts (25), 8 washers (27) and 4 studs (26),releasing the blade
(10).
– Position the new blade in the head assembly, insert 4 studs (26), fi t 8 washers (27) and 8 nuts (25).
Insert the latch spring (12) into the spacer (09).
Reassemble the latch (16) and tighten the 8 nuts.
– Fit the head assembly to the head support using the pin (24)
and circlip (23).
24
5. RETURN TO Cembre FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certifi cate supplied by Cembre together with the tool or fi ll in and attach
the form available in the "ASSISTANCE" section of the Cembre website.
5
27
25
26
09
13
07
25
23
12
28
16
FIG. 2
ENGLISH
10
14