EN
These instructions are for both the installer for
installation and the user for operation and main-
tenance of the product. After installation, please
hand them over to the user to keep.
Symbols and explanations
Attention! Warning against bodily injury or
damage to property.
Note, tip or reference
Correct installation/test of functionality
Incorrect installation
Observe installation details
Cold water
Water fl ow
Intended use
Single lever mixer tap for use in bathrooms
and WCs. Operation possible with pressure
tanks and thermally and hydraulically controlled
instantaneous water heaters. Operation with
unpressurised tanks (open water heaters) is not
possible!
Operation only with potable water.
Product is only suitable for installation indoors!
Attention! Only install in frost-free places.
4
Important information, please read!
Hot water
No water fl ow
Technical specifi cations
– Flow at 3 bar pressure:
– Pressure:
min. 0.5 bar/recommended 1-5 bar
– Operating pressure
– Test pressure:
– Recommended hot water inlet temperature:
– Water connection:
Avoid pressure differences between the cold and
hot water feeds.
Install a pressure reducer for static pressures
above 5 bar.
Installation dimensions, refer to page 2
Installation, refer to picture 1 on page 12
Flush potable water pipes thoroughly before and
after installation (observe EN 806 and 1717, as
well as DIN 1988).
Test connections for leaks with water pressure.
Operation, refer to picture 5 on page 12
Servicing, refer to picture 6 and 7 on page 12
Assemble in reverse order.
– Cartridge nut torque:
For spare parts with order numbers, refer to page 15.
For warranty and care information please refer
to the attached warranty and care instruc-
tions.
approx. 7.6 l/min
max. 10 bar
16 bar
max. 65°C
cold = blue marking
hot = red marking
12-13 Nm