SETTING this menu allows the user to adjust key
operation settings for this fixture. KEY select ON
for automatic lock-out. Password to re-enter the
display is UP + DOWN + UP + DOWN.
Select [DIM1], [DIM2], [DIM3] or [DIM4] for different
dimming speeds ([DIM4] is the slowest dimming
speed).
CURVE allows the user to adjust the shape of the
dmming curve. See the CURV chart to understand
more about actual dimming curves.
PERFORM this setting allows the user to select the
performance characteristics of the fixture.
LIVE mode is the default mode which balances the
requirements of output and noise.
STUDIO mode maintains extremely low noise at all
times and operates at a moderated power level.
POWER mode operates at high power for long peri-
ods of time without considerations for noise level.
SLOCK is use to lock settings menu. When SLCK
is set to ON the user must insert passcode (UP +
DOWN + UP + DOWN) in order to access the settings
CURV
DIMMING
menu.
PERSONALITY this settings allows the user to select
DMX personality of the fixture. Refer to DMX per-
sonality charts for specific details.
DMX ERROR Choose SAVE in order to save the last
DMX data incase of DMX signal error. Choose BACK
in order to blackout in case of DMX signal error.
In order to reset custom modes to default values
select RESET.
MODE SETTING this function allows the user to se-
lect whether the fixture will send DMX data to other
fixtures during stand-alone operation. The MAST
setting allows data to be sent to other fixtures. The
SELF setting is default and will not send DMX data
to other fixtures.
PWM_RATE is PWM reflesh rate bottom, press UP/
DOWN to choose 600Hz, 1200Hz, 2000Hz, 4000Hz,
25000Hz.
NOTE with reflesh rate increase, gray rate dimmer
will be reduced (that´s means high reflesh rate, low
gray rate), when it´s 4000Hz, CV3 is invalid, when
it´s 25000Hz, CV1 CV2 CV3 are invalid, so please
lower PWM rate to increase gray rate in necessary.
P. 7
English version
- Neo Elipsoled MAX