Important notes about the extraction mode
WARNING
Risk of poisoning from exhaust gases sucked back. Never operate
the device in extraction mode simultaneously with an open flue
appliance when there is not adequate airflow guaranteed.
Open fl ue combustion equipment (for example, gas, oil, wood or coal-fi red heaters,
tankless water heaters, water heaters) pulls combustion air from the room and runs
it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor
air is removed from the kitchen and the adjacent rooms - without suffi cient air intake
this creates a vacuum. Toxic gases from the chimney or extraction fl ue can thereby be
sucked back into the living spaces.
• Always ensure that a suffi cient supply of fresh air is guaranteed and that the air can
circulate.
• An air supply / extractor box alone does not ensure compliance with the limit
value.
Safe operation is only possible when the negative pressure in the room where the
appliance is located does not exceed 4 Pa (0.04 mbar). This can be achieved when
the air required for combustion can fl ow through openings that are not closable, for
example in doors, windows, in conjunction with an air supply / extractor box or
through other technical measures. In any case, consult a qualifi ed chimney sweep who
can assess the entire ventilation of your house and propose appropriate measures for
adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted operation is
possible.
Important note on disassembly of the device
• Disassembly is similar to installation/assembly in reverse order.
• Take a second person to help you during disassembly to avoid injuries.
EN
19