Sunex Tools SX4350 Instrucciones De Operación página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions • Warning Information • Parts Break down
fig. 1.
INSTRUCTION MANUAL
This product is designed to tighten or loosen threaded fasteners. No
other use is permitted.
AIR SUPPLY REQUIREMENTS
Tools operate on a wide range of air pressures. It is recommended
that air pressure measures 90 psig at the tool with the trigger fully
depressed and no load applied to the tool. Higher pressure (over 90
psig; 6.2 bar) raises performance beyond the rated capacity of the
tool, which will shorten tool life and could cause injury.
Always use clean, dry air. Dust, corrosive fumes and/or water in
the air line will cause damage to the tool. Drain the water from air
lines and compressor prior to running tool. Clean the air inlet filter
screen weekly. The recommended hookup procedure can be viewed
in the Figure 1.
The air inlet used for connecting air supply has standard 1/4" NPT.
Line pressure should be increased to compensate for unusually long
air hoses (over 25 feet). Minimum hose diameter should be 3/8"
I.D. and fittings should have the same inside dimensions and be
tightly secured.
Always turn off the air supply, drain hose of air pressure and detach
tool from air supply before installing, removing or adjusting any part
or accessory on this tool, or before performing any maintenance
on this tool.
Ensure an accessible emergency shut off valve has been installed in
the air supply line and make others aware of its location.
LUBRICATION
Lubricate the air motor daily with high quality air tool oil. If no air
line oiler is used, run 1/2 oz. of oil through the tool. The oil can
be squirted into the tool air inlet or into the hose at the nearest
con nec tion to the air supply, then run the tool. The oil plug is only
for adding multi-purpose grease after repair or maintenance of the
impact mechanism. Overfilling will cause a re duc tion in the power
of the tool.
WARNING: After an air tool has been lubricated, oil will
discharge through the exhaust port during the first few
seconds of operation. The exhaust port must be covered with
a towel before applying air pressure to prevent serious injury.
SX4350
Whip Hose
Do Not Install
Quick Coupling
Nipple
Here
Leader
Quick Coupler
Hose
Filter
Nipple
Oiler
Regulator
OPERATION
Always turn off the air supply, drain hose of air pressure and
detach tool from air supply before installing, removing or
adjusting any part or accessory on this tool, or before
performing any maintenance on this tool.
Soak rusted nuts in pen e trat ing oil and break rust seal before
removing with im pact wrench. If nut does not start to move in three
to five sec onds, use a larger size impact wrench. Do not use impact
wrench be yond rated ca pac i ty as this will dras ti cal ly reduce tool life.
NOTE: Actual torque on a fastener is directly related to joint
hardness, tool speed, condition of socket and the time the tool
is allowed to impact. Use the simplest possible tool-to-socket
hook up. Every connection absorbs energy and reduces power.
WARNING: Use only impact sockets and accessories on this tool.
Do not use hand sockets and accessories.
3
Air Supply
Drain Daily
Rev. 11/27/19

Publicidad

Tabla de contenido
loading

Tabla de contenido