Operating Instructions
Checking for Leaks
Burner Connections
Make sure the regulator valve and hose
connections are securely fastened to the
burner and the tank.
If your unit was assembled for you, visually
check the connection between the burner
pipe and orifice. Make sure the burner
pipe fits over the orifice.
WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire
or an explosion which can cause
death, serious bodily injury, or
damage to property.
Please refer to diagram for proper
installation.
If the burner pipe does not rest flush to
the orifice, please contact 1.800.762.1142
for assistance.
Tank/Gas Line Connection
Make 2-3 oz. of leak solution by mixing one
part liquid dishwashing soap with three parts
water.
Make sure control knobs are off.
Turn LP gas tank ON at valve.
Spoon leak check solution at all "x" locations
If any bubbles appear turn LP gas tank OFF,
reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect LP
gas source and contact 1.800.762.1142 for
assistance.
If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
Operating Main Burners
Lighting
1. Open lid. Attempting to light the
burner with the lid closed may
cause an explosion!
2. Make sure there are no
obstructions of airflow to the gas
unit. Spiders and insects can nest
within and clog the burner / venturi
tube at the orifice. A clogged
burner tube can lead to a fire
beneath the appliance.
3. All control knobs must be in the
OFF position.
4. Turn on gas at LP gas tank.
5. Push and turn control knob counterclockwise to HIGH.
6. Press the electronic igniter button and hold for 5 seconds to light burner.
7. If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes,
and repeat lighting procedure.
8. If igniter does not light burner, use a lit match secured with the lighting rod provided
to light burners manually. Access the burners through the cooking grid and heat
plates. Position the lit match near side of the burner.
Important: Always use the lighting rod provided when lighting burners with a match.
9. After lighting, observe the burner flame, make sure all burner ports are lit and flame
height matches illustration.
CAUTION: If burner flame goes out during operation, immediately
turn the gas "OFF" and open lid to let the gas clear for about 5
minutes before re-lighting.
Turning Off
1. Turn all control knobs clockwise to the OFF position one at a time.
2. Turn gas off at LP tank.
Initial Use
Before cooking on this grill for the first time, operate the grill for about 15 minutes with
the lid closed and the gas turned on "HIGH." This will "heat clean" the internal parts and
dissipate odor from the manufacturing processes.
Gas Valve
with orifice
Burner
Venturi
Gas
Connections
Main Burners
Gas
Connections
Burner
Venturi
Gas Valve
with orifice
Side Burner
X
X
X
X
X
12.7 mm
Flame
Burner
6.4mm
Main burner proper flame height.
Outdoor LP Gas Barbecue Grill Model No. NSG3902D
Direct Cooking
1. Light burners per lighting instructions.
2. Set burners to desired level and allow temperature to be reached.
3. Place food directly over burners.
4. With lid open or closed, cook untill desired internal temperatures are acheived.
Indirect Cooking
Ideal for roasts and larger cuts of meat.
1. Remove cooking grid.
2. Place metal tray in center, on heat plates.
3. Replace cooking grid.
4. Light burners.
5. Turn center burner off. Set ouside burners to desired level and allow temperature to
be reached.
6. Place food on cooking grid, directly over metal tray.
7. With lid closed, cook until desired internal temperatures are achieved.
Tips For Better Cook Outs and Longer Product Life
1. Spray or coat cooking surfaces with vegetable oil before cooking to avoid sticking.
2. Place vegetables or delicate foods into aluminum foil pouches.
3. Use a quality grill brush after each event to keep cooking surfaces clean and rust free.
4. Empty grease pan after every use.
CAUTION: Do not cover grill until it is completely cool to the touch.
Operating Side Burner
NOTE: Side burner can be used while main burners are operating.
Never use side burner as a grill.
Lighting
1. Open lid. Attempting to light the
burner with the lid closed may
cause an explosion!
2. Make sure there are no
obstructions of airflow to the gas
unit. Spiders and insects can nest
within and clog the burner / venturi
tube at the orifice. A clogged
burner tube can lead to a fire
beneath the appliance.
3. Control knob must be in the OFF
position.
4. Turn on gas at LP gas tank.
1/2"
5. Push and turn control knob counterclockwise to HIGH.
6. Press the electronic igniter button and hold for 5 seconds to light burner.
1/4"
7. If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes,
and repeat lighting procedure.
0"
8. If igniter does not light burner, use a lit match secured with the lighting rod provided
0mm
to light burners manually. Position the lit match near side of the burner.
Important: Always use the lighting rod provided when lighting burners with a match.
9. After lighting, please observe the burner flame, make sure all burner ports are lit and
flame height matches illustration.
CAUTION: If burner flame goes out during operation, immediately
turn the gas "OFF" and open lid to let the gas clear for about 5
minutes before re-lighting.
Turning Off
1. Turn control knob clockwise to the OFF position.
2. Turn gas off at LP gas tank.
Cooking
1. Light burner.
2. Set burner to desired temperature
3. Place pan on center of grid.
4. Cook and adjust temperature as needed.
Flame
Burner
0"
3/8"
3/4"
0 mm
9.5 mm
19 mm
Side burner proper flame height.