Remedy Of Faults - Oase InScenio FM-Master 1 Instrucciones De Uso

Distribuidor de corriente eléctrica
Ocultar thumbs Ver también para InScenio FM-Master 1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
- GB -
Prior to being able to start up the unit, harmonise the manual transmitter transmit signal with the receiver in the unit.
For this purpose, the receiver is equipped with a teach-in key.
How to teach-in the manual transmitter (D):
Insert the teach-in pin (5) into the opening (8) until you feel a resistance. At this point you have reached the teach-in
key.
Briefly press the teach-in key using the teach-in pin.
Keep any button of the manual transmitter pressed for at least 3 sec.
This completes the teaching in of the receiver to the manual transmitter.
Deleting saved manual transmitters
How to delete the manual transmitters from the unit:
Keep the teach-in key of the unit pressed for at least 5 sec. using the teach-in pin (5).
All saved manual transmitters are deleted.
Connect the units to the power supply distributor
This is how to connect your OASE unit to the power supply distributor:
If necessary, remove the protection hood from the power supply distributor.
Select a suitable socket from the following table.
Make sure that your OASE unit may be connected to this socket. For this purpose, consult the instructions of use of
the unit you wish to connect.
The following is to be taken into consideration: Units powered via a transformer may not be connected to a socket
with dimmer function.
Connect the unit.
Always use the pull relief (E, 9) provided on the unit for the connection cables.
Refit the protection hood to the unit.
Operation
How to operate the manual transmitter:
LED Control lamp
O
switch off
I
switch on:
– +
dim

Remedy of faults

Malfunction
Unit does not respond to commands from the
manual transmitter
10
17261-06-14_GA_InScenio FM-Maste10 10
InScenio FM-Master 1
1 Socket 1, with switch
function
2 Socket 2, with switch
function
3 Socket 3, permanent
4 Socket 4, permanent
InScenio FM-Master 1 InScenio FM-Master 2 InScenio FM-Master 3
a Socket 1, switch
b Socket 2, switch
c no function
d no function
Cause
Receiver in the unit does not receive from the ma-
nual transmitter
Interference over radio distance
Receiver in the unit defective
Dead battery in the manual transmitter
(LED of the manual transmitter does is not lit)
Fine fuse has tripped because an unsuitable unit
was connected to the socket with dimmer function
(only InScenio FM-Master 1, 2, 3)
InScenio FM-Master 2
1 Socket 1, with switch
function
2 Socket 2, with switch
function
3 Socket 3, permanent
4 Socket 4, with switch
function
a Socket 1, switch
b Socket 2, switch
c Socket 4, switch
d no function
Teach-in manual transmitter
Choose a different place, ensure unob-
structed view
Contact the OASE service
Change battery
Replace fuse
Only connect suitable devices to a socket
with dimmer function
04.06.2014 10:04:19
InScenio FM-Master 3
1 Socket 1, with switch func-
tion
2 Socket 2, with switch func-
tion
3 Socket 3, permanent
4 Socket 4, with switch and
dimmer function
a Socket 1, switch
b Socket 2, switch
c Socket 4, switch
d Socket 4, dim
Remedy

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Inscenio fm-master 3Inscenio fm-master 2

Tabla de contenido