Operation
1
Connecting power
Plug the pump power cord plug into the piggyback switch
plug outlet.
Plug the switch plug into a 115V GFCI power outlet.
Care and Cleaning
To clear a pump that is clogged with debris:
Unplug the pump to disconnect the electrical power.
Unscrew the four screws (4) on the pump body and
remove the volute (1) and O-ring (2).
Remove debris from around the impeller (3).
Reassemble the pump.
2
Operating the pump
When the float switch (1) moves up over the top of the
pump, the pump begins to operate. When the water lowers
to a certain level, the float switch (1) will turn the pump off.
NOTE: Ensure the pump is submerged in water. Running the
pump dry can damage the pump.
7
Please contact 1-844-883-1872 for further assistance.
1
HOMEDEPOT.COM