Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
1. Remove the existing light fixture.
2. Install the mounting strap as shown using two screws
that fit your junction box.
3. The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
4. Route the light control's wires through the large
gasket holes.
5. Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mounting
Black to
Strap
Black
Junction box ground wire to
green ground screw on fixture.
204054-03
White to
White
Rubber
Plug
Mounting
Bolt
Gasket
Mount the Light Control
1. Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
2. Push the rubber plug firmly into place.
3. If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
To avoid water damage and electrical shock,
keep bulb holders 30° below horizontal.
Lock Nut
Lens
4. Adjust the bulb holders by loosening the lock nuts
but do not rotate the bulb holders more than 180°
from the factory setting. When screwing in the flood
lamps, do not overtighten.
3
Keep bulbs at least
1" (25 mm) from the
sensor. Do not allow
the bulbs to block
the lens.