Beninca THINK Manual De Usario página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
MENU
The automatic closure is enabled or disabled.
TCA
Off: disabled automatic closure.
On: enabled automatic closure.
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
IbL
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the
impulse of the transmitter has no effect in the opening phase.
The rapid closure is enabled or disabled.
On: enabled rapid closure. With open gate or gate in the opening phase, the
SCL
activation of the photocell causes the automatic closure of the gate 3 sec
after its activation. This function is enabled only with TCA:ON
Off: rapid closure disabled.
The operating mode The operating mode of the "P.P." (Step-by Step) button
and of the transmitter is selected.
PP
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation : OPEN > CLOSE > OPEN >
Forewarning flashing light enabled or disabled.
Off: disabled forewarning flashing light.
PRE
On: enabled forewarning flashing light. The flashing light is activated 3 sec
before the motor starts.
The OPEN input mode is selected.
Off: OPEN input, with OPEN function.
CLOC
On: OPEN input, with CLOCK function.
To be used for connection to timer for timed opening/closing. (CLOSED con-
tact: open gate. OPEN contact: normal operation).
The Service Man function is enabled or disabled.
Off: Automatic operation.
htr
On: Service Man operation.
The OPEN/CLOSE push-buttons should be kept pressed for the entire oper-
ating time.
The lock function is enabled or disabled.
Off: Lock function disabled.
On: Lock function enabled. After the triggering of the closure limit switches,
BLC
the control unit delays the stop by approx. 0.5sec in order to allow a better
resting of the gate leaf onto the stoppers. DAS input is activated in the clos-
ing phase only.
Note: In case of sliding gates, leave to OFF.
Photocell 1 input in the opening phase is enabled or disabled.
Pho1
On: Photocell 1 is activated in the closing phase only.
Off: Photocell 1 is activated in both opening and closing phases.
Photocell 2 input in the opening phase is enabled or disabled.
Pho2
On: Photocell 2 is activated in the closing phase only.
Off: Photocell 2 is activated in both opening and closing phases.
Photocell 3 input in the opening phase is enabled or disabled.
Pho3
On: Photocell 3 is activated in the closing phase only.
Off: Photocell 3 is activated in both opening and closing phases.
Photocell 4 input in the opening phase is enabled or disabled.
Pho4
On: Photocell 4 is activated in the closing phase only.
Off: Photocell 4 is activated in both opening and closing phases.
The operating mode of output SCA/TESTPHOT is selected.
On: Photocell power supply in Test mode as per diagram at page 4. Before
TSTP
each operation all PHOT inputs are checked. If the result is negative, the
operation will not take place.
Off: Output preset as open gate warning LED.
The check function of single failure is enabled or disabled.
Off: Single failure check is disabled.
Faut
On: Single failure check enabled in compliance with the Machinery Directive
98/37/CE.
The anti-crash amperometric sensor is disabled or enabled. Its sensitivity is
adjusted by parameters SNSO and SNSC.
AMP
On: Amperometric sensor activated.
Off: Amperometric sensor deactivated.
FUNCTION
Settable values
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Think-iThink-p

Tabla de contenido