Cleaning And Maintenance; Replacing The Fuse - EuroLite TS-7B Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Control-channel 5 - Shutter, strobe
Decimal Hexad. Percentage S/F
0 14
00 0E
0% 5%
15 29
0F 1D
6% 11%
30 250 1E FA
12% 98%
251 255 FB FF
98% 100%
Control-channel 6 - Dimmer intensity
Decimal Hexad. Percentage S/F
0 255
00 FF
0% 100%

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service
operations are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamps".

Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuseholder on the rearpanel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
S Shutter closed
S No function (shutter open)
F Strobe-effect with increasing speed (max. 7 flashes/sec.)
S No function (shutter open)
F Gradual adjustment of the dimmer intensity from 0 to 100 %
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
Feature
Feature
27/54
00026556.DOC, Version1.3

Publicidad

Tabla de contenido
loading

Tabla de contenido