8.1 Error codes on the display
Error code
E0
E1
E2
Ft
9
TECHNICAL SPECIFICATIONS
• Cooling capacity: 7000 Btu
• EER: Class A
• Power supply: 220 - 240 V / 50 Hz
• Sound pressure level: ≤54 dB (A)
• Sound power level: ≤65 dB
• Rated input (cooling): 780 W
• Rated current (cooling): 3.5 A
• EER for cooling: 2.61
• Refrigerant/Charge: R290/120g
• Dehumidifying capacity: 19.2 L / day
• Air circulation: 290 m
• Body size: 300 x 300 x 700 mm
10 DISPOSAL OF USED ELECTRIC AND ELECTRONIC EQUIPMENT
The meaning of the symbol on the material, its accessory or packaging indicates that this
product shall not be treated as household waste. Please, dispose of this equipment at your
applicable collection point for the recycling of electrical and electronic equipments waste.
In the European Union and other European countries which there are separate collection
systems for used electrical and electronic product. By ensuring the correct disposal of this
product, you will help prevent potentially hazardous to the environment and to human
health, which could otherwise be caused by unsuitable waste handling of this product. The
recycling of materials will help conserve natural resources. Please do not therefore dispose
of your old electrical and electronic equipment with your household waste.
For more detailed information about recycling of this product, please contact your local
city office, your household waste disposal service or the shop where you purchased the
product.
Possible cause
Communication fault
between PCB and display.
Temperature sensor is
broken.
Coil temperature sensor is
broken.
High water level in the
reservoir.
/h
3
Solution
Contact your reseller.
Empty the reservoir.