G
B
A - CONTROL PANEL FEATURES
J2
J9
J10
J8
J7
S3
J1
F1
J3
TRANSFORMER
J4
FUSE 1
J5
J6
TR3
TR1
TR2
N F
J1
J2
COM.
CLOSE
OPEN
STOP
AERIAL
J3
SIGNAL
A+TEST
EDGE N.C.
COM.
PHOTO N.C.
K BUTT.
PED. BUTT.
A+
A -
LOCK
J4
SECONDARY
TRANSFORMER
J5
MOTOR 1
J6
MOTOR 2
J7
SW T2 24V
J8
SW RADIO
J9
RADIO
J10
BATTERY CHARGER
TR1
TRIMMER RUN
TR2
TRIMMER LOW SPEED
TR3
TRIMMER TCA
S3
PROG
FUSE 1
T 8 A
F1
T 2 A
32
Power supply 230 Vac 50/60 Hz - external to the
control panel - (120V/60Hz upon request)
Common contact
Closing impulse contact (NA)
Opening impulse contact (NA)
STOP impulse contact (NC)
Radio Antenna
Gate open state and battery state output
indicator (24Vdc 3W max)
+ 24Vdc safety strip self-test power supply
Safety strip contact (NC)
Common contact
Photocells contact (NC)
Single pulse contact (NO)
Pedestrian opening contact (NA)
+ 24Vdc accessories power supply
- 24Vdc accessories power supply
Electric lock connection (MAX 15W 12V)
- 24Vdc blinker (code ACG7061) power
supply. Pay attention to the polarity.
Connection to secondary coil of transformer 18 Vac
MOTOR 1 CONNECTION (without polarity)
MOTOR 2 CONNECTION (without polarity)
Connector dedicated to the factory programming.
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Connector dedicated to the factory programming
(only CRX control board)
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Built-in radio module (model CRX), or connector for
radio receiver RIB, 24 Vdc supply
Connector for charge card of 24Vdc battery
(code ACG4648)
Trimmer for high speed adjustment operations
Trimmer for low speed adjustment operations
Trimmer for automatic closing time adjustment
(DISABLED DEFAULT AND DL6 LED OFF)
Programming button
Motor protection fuse
Transformer protection fuse