MAINTENANCE AND INSPECTION

WARNING
● Be sure to switch power OFF and disconnect the plug from the receptacle during maintenance and
inspection.
● Using cracked, deformed or damaged wheels can lead to wheel breakage and resulting serious injury.
1. Replacing the depressed center wheel
Replace the depressed center wheel when it has been
worn out to about 2-3/8" (60mm) in external diameter.
Confi rm that there is no crack or any damage to
the depressed center wheel. If there is a crack or a
transformation in the wheel, replace it immediately.
2. Inspecting the screws
Regularly inspect all screws and ensure that they are
fully tightened. Should any of the screws be loosened,
retighten them immediately.
WARNING
Using this grinder with loosened screws is
extremely dangerous.
3. Confi rm that there is no damage in the wheel guard,
the electrical cord and the housing, etc.
Check that the on/off switch operates normally.
4. Replacing supply cord
If the supply cord of Tool is damaged, the Tool must
be returned to metabo HPT Authorized Service
Center for the cord to be replaced.
5. Service and repairs
All quality power tools will eventually require
servicing or replacement of parts because of wear
from normal use. To assure that only authorized
replacement parts will be used, all service and
repairs must be performed by a metabo HPT
AUTHORIZED SERVICE CENTER, ONLY.
6. Filter cleaning and replacement
WARNING
Wear protective glasses and a dust mask when
cleaning the fi lter with an air blow gun.
Failure to do so may result in inhalation or
exposure of the eyes to debris or dust.
Remove any debris or dust adhering to the fi lter after
use. Check the fi lter periodically to ensure that it is
free of scratching, chipping, or tearing. Replace with a
new fi lter if the fi lter is damaged in any way.
12
NOTE
Use an air blow gun to completely remove debris and
dust from the mesh parts of the fi lter. (Fig. 6)
Air blow gun
7. Filter set inspection and replacement
Removal procedure (Fig. 7)
(1) Loosen the two clips on the bottom and side fi lters
with a fl athead screwdriver.
(2) Detaching the bottom fi lter from the main unit allows
removal of the two side fi lters.
Flathead
screwdriver
Side fi lter
Filter set
Mesh
Fig. 6
Bottom fi lter
Side fi lter
Fig. 7