English
WARNING:
Check the manufacturer's maximum
pressure rating for nailers, staplers
and accessories. Compressor outlet
pressure must be regulated so as to
never exceed the maximum pressure
rating of the nailers, staplers and
accessories.
Knob of the pressure switch
Pressure gauge (A)
indicates the pressure in
the air tank
3. Shutdown
(1) Push the knob of the pressure switch to "OFF". (Fig. 1)
(2) Unplug the plug from power source.
(3) Open the drain cock located at the lower part of
the tank (Fig. 3).
Drain cock
Knob of
the pressure
reducer
Joint
Pressure gauge (B)
indicates the working
pressure
Fig. 2
Tank
Fig. 3
MAINTENANCE
WARNING:
Disconnect the compressor from the
power source and remove the
compressed air from the air tank
before performing the maintenance
operations.
1. Cleaning the intake filter
Remove the intake filter (Refer to Fig. 1.) every 50
hours or once a week and clean the inside of the
intake filter and the filter element with compressed
air. (Fig. 4)
Use a phillips screwdriver to disassemble intake filter.
WARNING:
Never clean filter element with a
flammable liquid or solvent.
NOTE:
Replace the filter element when it becomes dirty.
2. Draining tank
Drain tank daily or after 4 hours of use. Open drain
fitting and tilt compressor to empty accumulated
water. (Fig. 3).
SERVICE AND REPAIRS
All quality compressors will eventually require servicing
or replacement of parts because of wear from normal use.
To assure that only authorized replacement parts will be
used, all service and repairs must be performed by a
HITACHI AUTHORIZED SERVICE CENTER, ONLY.
NOTE:
Specifications are subject to change without any
obligation on the part of the HITACHI.
— 10 —
Filter element
Intake filter
Fig. 4