4 Technical data
4.1 Rotary hammer
Note
When powered by a generator or transformer, the generator or transformer's power output must be at
least twice the rated input power shown on the rating plate of the electric tool. The operating voltage
of the transformer or generator must always be within +5% and -15% of the rated voltage of the
electric tool.
The information given applies to a rated voltage of 230 V. The data may vary in the event of deviations
from the rated voltage and for country-specific versions. Please refer to the electric tool's type
identification plate for details of its voltage, frequency, current and input power ratings.
Rated power input
Rated current input
Weight in accordance with EPTA
procedure 01/2003
Single impact energy in accordance
with EPTA procedure 05/2009
Ø Hammer drill bits
Maximum length of the depth gauge 180 mm
4.2 Noise information and vibration values determined in accordance with EN 60745
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one electric tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the electric
tool. However, if the electric tool is used for different applications, with different accessory tools, or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This may significantly reduce exposure over
the total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: maintenance of the electric tool and the accessories, keeping the hands warm,
organization of work patterns.
Noise emission values determined in accordance with EN 60745
Sound (power) level (L
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration (vector sum of three directions), measured in accordance with EN 60745-2-6
Hammer drilling in concrete (a
Uncertainty for the given vibration value (K)
5 Operation
Fitting the side handle
CAUTION
Risk of injury The depth gauge, if fitted but not used, may hinder the operator.
▶ Remove the depth gauge from the tool.
CAUTION
Risk of injury Loss of control over the rotary hammer.
▶ Check that the side handle is fitted correctly and tightened securely. Check that the
clamping band is engaged in the groove provided on the tool.
TE 1
650 W
3.0 A
2.4 kg
1.5 J
4 mm ... 18 mm
)
WA
)
WA
)
pA
pA
)
h, HD
100 dB(A)
3 dB(A)
89 dB(A)
)
3 dB(A)
15 m/s²
1.5 m/s²
2
13