Descargar Imprimir esta página

Palazzetti ECOFIRE ALLEGRO V1 Manual De Instrucciones página 9

Publicidad

SCHEMA ELETTRICO - WIRING DIAGRAM - SCHÉMA DE CÂBLAGE
ELEKTRISCHER SCHALTPLAN - DIAGRAMA DE CABLEADO - EL-DIAGRAM
1.HALL SPEED SENSOR
2.EXTERNAL THERMOSTAT
3.ROOM PROBE
4.PELLET PROBE
K
5.FLUE GAS TEMP.
Pa
6.PRESSURE SENSOR
7.IGNITER
comb
8.COMBUSTION FAN
10.PELLET AUGER
11.STB SAFETY
Pa
12.UNDER PRESSURE SAFETY
13.DOOR OPEN
Air
14.ROOM FAN
Air
15.DIMMER
16.INDUCTANCE
UI /
USER INTERFACE or
PC
PC CONNECTION
NOTE:
Phase protection, added by customer.
Do not change polarity!
ITALIANO
Sensore di hall
1
Termostato esterno
2
Sonda ambiente
3
Sonda pellet
4
Sonda fumi
5
Differenziale di
6
pressione
Resistenza ad
7
incandescenza
Ventilatore scarico
8
fumi
Dosatore
10
caricamento
Termostato di
11
sicurezza
Pressostato
12
Sensore porte
13
Ventilatore
air
14
ambiente*
Dimmer
15
UI /
Pannello comandi
PC
t° R
2
UI /
PC
ext 5-6
+16V
LD2
LD1
CN12
L ~230 N
1
7
2
PE
L
N
230 Vac
* Solo nei modelli ventilatore con condensatore / Only in
models with a condenser room fan.
** Solo nei modelli con microinterruttori sulla portina o sul
coperchio serbatoio./ Only where microswitches are provided
ENGLISH
FRANCAIS
Exhaust fan speed
Capteur de hall
sensor
Thermostat
Thermostat
Room probe
Sonde ambiant
Pellet probe
Sonde pellet
Flue probe
Sonde des fumees
Differential de
Pressure differential
pression
Igniter
Resistance
Extracteur des
Exhaust fan
fumees
Systeme
Feeding system
d'alimentation
Thermostat
Thermostat
Vacuum switch
Pressostat
Door sensor
Sonde porte
Room fan *
Ventilateur ambiant* Raumluftgeblaese*
Dimmer
Dimmer
Tableau de
Display
commande
t° L
2
3
1
ext 3-4
T05
I04
GND
F01
F03
+5V
I03
GND
F02
GND
CN5
CN7
air
CN3
CN1
O01
O02
O03
16*
*
comb
Air
8
14
10
13**
DEUTSCH
Hall fuehler
Raumtemperaturregler Termostato
Raumsonde
Pelletsonde
Rauchsonde
Druckdifferenzial-
sensor
Glutwiderstand
Abgasventilator
Spender
Raumtemperaturregler Termostato
Druckwaechter
Tuersonde
Dimmer
Steuerpaneel
K
5
4
ext 1-2
T01
T02
T03
T04
Pa-
CN6
CN9
CN10
O04
I01
I02
O05
Air R
Pa
12
13**
11
ESPAÑOL
Sonda regulad.
Veloc. Turbina
humos
Sonda ambiente
Sonda pellet
Sonda humos
Diferencial de
presion
Resistencia
Turbina expulsion
humos
Dosador
Presostato
Sensor puerta
Ventilador de
conveccion*
Dimmer
Panel de mando
2
6
Pa
Pa+
CN11
CN2
O07
O06
14
14
Air L
16
16
15
15
cod. 00 472 3796 24/10/16
SLOVENSKO
Senzor hall
Termostat
Sobna sonda
Sonda za pelete
Sonda za dimne
pline
Diferen nega tlaka
Grelni element
Ventilator za odvajanje
dimnih plinov
Dozator za pelete
Varnostni termostat
Merilec tlaka
Senzor za vrata
Ventilator*
Dimmer
Krmilna ploš a
9

Publicidad

loading