3.2.2 Electronic Control
ONLY FREZERS MODELS (Example: EDUF)
After connecting your unit, turn ON rocker switch located next to the controller. The display will
light up showing the temperature inside the unit. Also, the compressor and fan icons will flash
for a period of three minutes. After this delay the unit will start cooling.
Verify you don't have any alarms on the temperature controller. If after you turn ON the
equipment the controller shows the alarm icon or an error code, call for technical service. They
will help you fix the problem.
FIGURE 3
Temperature inside the cabinet
Compressor Icon
Evaporator Fan Icon
3.3 Machine settings and programs
Changing the Set Point of the temperature on the controller
The unit comes with a factory default set point ( 0°F(-18°C) Freezers). These set values will make the
unit perform at its maximum capacity. Therefore, it is not recommended to change the set point. If set
point needs to be changed, follow the next steps.
1. Push the SET button for one second. You should see a flashing number. Release the
button.
2. Press the up and down arrows to increase or decrease the set temperature. Then press the
set button to save the new set point.
Note:
The maximum value you can set in the controller is: For freezer: 2°F (-16°C)
3. If you wish decrease the value of the set point for a new temperature, press the button
DOWN arrow (see the picture below). Press this button to reach the desired value. Release
the button and then press the SET button to keep, and save, the new value.
Note:The minimum value you can set in the controller is: For freezer: -9°F (-23°C)
Manual Defrost
To set a manual defrost, hold the button DOWN arrow for 5 seconds. The snow flake icon will appear on
the display. When this icon is solid it indicates that the equipment is in Defrost mode.
To exit manual defrost, hold the DOWN button arrow for 5 seconds. The snow flake icon will turn off.
Wait 2 minutes for the compressor to start.
To increase Set Point of Temperature
To turn the unit ON/OFF without unplugging the
equipment
To Change the set point
To access programming
mode
To decrease Set Point of Temperature
To set a manual defrost
6