CORD PROTECTOR
FH-00F150 OR FH-00F152
1800mm POWER
CORD
HOT
HOT
GROUND
230 VOLT OR AVAILABLE VOLTAGE BETWEEN 220-240V
ELECTRICAL REQUIREMENTS:
Apply power by connecting the power cord to a properly installed junction box
powered with 230V, or between 220-240V per the nominal national voltage. A typical
wiring diagram is shown above.
Connect heat pads only to power sources which are protected by Ground
Fault Interrupter (GFI) circuits and installed by a certified electrician. Failure
to use GFI protected circuits exposes animals and user to dangerous
electrical shock hazard.
Heat pads do not usually raise the air temperature measurably except in confined
spaces. Also the surface does not feel extremely warm to the touch. Heat pads are a
thermal barrier and prevent heat loss from the animal. This helps maintain a constant
body temperature, especially during sleep. When power is first applied, some heat loss
to the floor occurs, but decreases as the floor is warmed.
CLEANING INSTRUCTIONS:
Always disconnect electricity before washing or pressure washing. Unnoticed
damage could cause electrical shock hazard.
Heat pads may be safely high-pressure washed, brushed, scraped and immersed in
water or disinfectant. Thoroughly dry heat pads after washing. Maintain dry operating
conditions. Osborne Stanfield
Heat Pads are water-resistant, but continuous exposure
®
to moisture or urine leads to early failure.
____________________________
____________________________
____________________________
____________________________
BOX 388
Osborne, KS 67473
USA
JUNCTION BOX
GROUND WIRES
CONNECTED TOGETHER
DISCONNECT SWITCH
DOUBLE POLE
DRIP PROOF SWITCH COVER
WARNING
WARNING
HEAT PAD
WIRED BY LICENSED
ELECTRICIAN PER LOCAL
ELECTRICAL CODE USING
CERTIFIED COMPONENTS
Do not allow bedding, manure, or debris to cover heat pad. Do not cover
heat pad with any flammable covering. Any covering causes the heat pad to
become too warm for the animal, is a fuel source for fire, and reduces the life
Osborne Industries, Inc., warrants its heat pads and controls to be free of
defects in materials and workmanship under normal use for a period of ONE
YEAR from the date of purchase. Power cords and sensor extensions are
not included in this warranty. Any heat pad or control which our examination
reveals to be defective will be repaired or replaced at our option without
charge. Alleged defective products must be returned in a clean condition
to the retailer from whom the product was purchased or to any Authorized
Osborne Dealer. If a warranty registration card is not returned when pur-
chased, returned products must include a copy of the original sales slip
showing purchase date and serial number (imbedded in the back surface
of heat pad). Owner's name and address must be clearly marked on the
product. The serial number or date of shipment from the factory is used to
determine warranty period if products are not registered or accompanied by
proof of purchase. Osborne Industries, Inc., is not liable for loss or damage
resulting from alteration, misuse, or abuse of the products. This warranty
is limited to repair or replacement of the product and excludes conse-
quential and special damages.
Manufactured by: Osborne Industries, Inc. · Box 388 · Osborne, KS 67473 · USA
PLACE
STAMP
HERE
WARNING
expectancy for the heat pad. Keep it clean and dry.
WARRANTY STATEMENT
Printed in the USA · RLX-0560_B
SPACE REQUIREMENTS
FOR HEAT PADS
MODEL
SPACE
NUMBER
REQUIRED (cm)
REHS1B3
31 x 92
REHS1B4
31 x 122
REHS1B5
31 x 153
REHS2B3
61 x 92
REHS2B4
61 x 122
REHS2B5
61 x 153
REHS120
64 x 99
REHS203
61 x 92
REHS303
92 x 92
REHS304
92 x 122
REHS1824