I N STA L L AT I O N I NS TRUC TION S
•
Gas stoves produce heat and humidity.
•
Make sure that there is a good airflow by installing a stove hood to extract
heated air. Additional fresh air ventilation through a window or door should be
available in the area. Poor ventilation can deplete oxygen, which endangers
health as well the performance of your gas stove.
•
If using your gas stove for an extended period of time, extra ventilation will be
necessary to increase the airflow.
•
Do not allow drafts to diminish the performance of the stove or to extinguish the
gas flame.
•
To install your gas stove to a LPG (Liquefied Petroleum Gas) pipe, make
sure your hose has a gas pipe converter in good working condition that is
manufactured specifically for your stove.
•
Since your gas stove is equipped with electric ignition, use the correct electrical
plug and outlet for your stove. The outlet should be in good working condition.
•
Never install the stove on carpeting.
•
Do not install the stove near the refrigerator, as excessive heat will hinder its
performance.
CLEARANCE:
•
Leave at least 80 to 85 cm between the top of the gas stove and
cabinetry or a planned or installed stove hood.
•
Leave at least 2 cm in the back and on each side of the gas
stove to allow heat to circulate.
GAS STOVE INSTALLATION:
•
This stove was designed for use with LP gas.
•
Always use a pressure regulator designed specifically for your
gas stove. The lack of a pressure regulator could cause excess
pressure and dangerous gas leakage. Check the pressure
regulator reading frequently to determine that the pressure level
is safe. The hose and regulator should be replaced every 5
years. The technical specification of the pressure regulator is:
• Pressure: 200 mm C.A.
• Maximum consumption: 2 kg/h
•
Use a PVC hose that can handle temperatures from 20° C to 100° C. Be sure
the hose:
• Does not have joints.
• Does not directly touch the back of the stove and is not confined in a tight
area able to trap extremely high temperatures.
• Is less then 125 cm long.
En gl ish -4
80 to 85cm
2cm
Pressure Regulator