Technical Data; Troubleshooting - Balluff BAE SA-XE-051-XR Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
Instruction manual BAE SA-XE-051-XR

Technical data

EU Examination of Conformity
IECEx Certificate
Ignition protection type (ATEX): Gas-Ex
Ignition protection type (IECEx): Gas-Ex
Control circuit / maximum values
Uo
Io
Po
Capacitance and inductance / maximum values
Group
IIC
IIB
IIA
Control circuit
Contact circuit / maximum values
Voltage max.
Current max.
Load cos φ
L / R
Rated voltage
Supply Voltage
Power consumption
Ambient temperature range
Test voltage
Degree of protection EN 60529
Electrical connection
Trouble shooting
Failure
Functional display
does not lit
No change of
switching signal
Scope of delivery, transportation and disposal
• Inspect packaging and content for damage.
• Check the delivery for completeness.
• Disposal note: Do not dispose the device in the domestic waste, comply with relevant laws and national regulations.
BA-S36066-GB-2018-10
Dust-Ex
Dust-Ex
Cause of failure
Supply voltage too low or
not connected
Use of the connected sensor
outside of specification
EPS 17 ATEX 1 180
IECEx EPS 17.0092
II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
[Ex ia Ga] IIC
[Ex ia Da] IIIC
9.6 V
10.1 mA
24.2 mW
linear characteristic
Co
Lo
0.84 µF
5.00 mH
3.40 µF
20.00 mH
4.90 µF
20.00 mH
NAMUR, DIN EN 60947-5-6 / IEC 60947-5-6
250 V AC
60 V DC
4 A
0.8 A
≥0,7
≤200 ms
30 V DC
24 V DC ±10%
0.5 VA
– 20 °C ≤ Ta ≤ +60 °C
1500 V / 50 Hz / 60 s
IP 20
terminal screws, wire cross-section 0.14...2.5 mm�
Remedy
Check power supply
Check range of
application of the sensor
Page 2
24 V DC
4 A
≤200 ms

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bae00zu

Tabla de contenido