20/21
9. Air Nozzle Kits (Air consumption)
Boquilla
2.2 B
210 L/min. at 3.5 bar
2.8 B
220 L/min. at 3.5 bar
3.2 B
220 L/min. at 3.5 bar
PD01
10. Start-up
Before each start-up and especially after cleaning or repairing the unit, a check must be made that
all its elements are securely tightened.
If maintenance or repair work is to be carried out, the gun must be depressurised before work
begins (without air pressure). Should this safety measure not be observed, this may lead to
malfunctions, personal injury and accidents, which may prove to be fatal. SAGOLA S.A. does not
accept any responsibility for the consequences of any non-compliance with these safety regulations.
Open the spray width and product regulators complete-
ly (without removing these from their housing) by
turning these anticlockwise.
Connect the gun to the compressed air network.
When assembling the equipment, make sure to connect
the air hose to air conduits (1) and the product hose to
the product conduits (2). Regulate product pressure to
the gun by applying product pressure until this fails from
15 to 20 cm. from the gun, depending upon the product
to be applied.
Adjust the air pressure in hte network regulator in order
to compensate for any pressure drop in the network
(estimated at 0.6 bar for each 10 m. of hose).
Adjust the air pressure in the air nozzle by operating the
flow regulator until the required quality of finish is
obtained (better finishes are not obtained with higher
spraying pressures and these lead to lower performan-
ce and worse product transfer).
· PD version: Position the air nozzle spraying orifices
appropriately perpendicular to the floor. Fully close the
product regulator by turning it clockwise. Turn the
product regulator until the "0" coincides with the arrow; and perform the desired application test,
adjusting the product regulators and range as follows:
Open the product regulator until the appropriate amount of product comes out. Now you have the
maximum spraying width (spraying pattern). You can reduce this according to your needs by
closing the spray width regulator.
Gotelé
PD
300 L/min. at 2 bar
ENGLISH
Gotele aircap
2
1
15-20 cm
PD Aircap
SAGOLA
6110 INOX