Operation With Portable Generator; Storing, Transporting Or Shipping; Preventative Maintenance Schedule - Procom Heating PPK145T El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION WITH PORTABLE GENERATOR

WARNING: Before operating
heater or any appliance from a
portable generator, verify that
generator has been properly con-
nected to earth ground. Improper
grounding or failure to ground
generator can result in electro-
cution if a ground fault occurs.
Refer to owner's manual supplied
by generator manufacturer for
proper grounding procedures.
Operating voltage range of heater is 95 to 135
Volts. Prior to plugging heater into generator
output voltage should be verified (if generator
is equipped with automatic idle feature, output
voltage should be measured with generator
running at full speed). If voltage does not

STORING, TRANSPORTING OR SHIPPING

Note: If shipping, transport companies require
fuel tanks to be empty.
1. Remove excess fuel from tank using a si-
phon pump. Drain remaining fuel through
filler neck by tipping heater to the rear.
2. If any debris is noted in old fuel, add 1 or 2
quarts of clean kerosene to tank, stir and
drain again. This will prevent excess debris
from clogging filters during future use.

PREVENTATIVE MAINTENANCE SCHEDULE

WARNING: Never service heater while it is plugged in, operating
or hot. Severe burns and electrical shock can occur.
Item
How Often
Fuel tank
Clean every season or as needed.
Air output and
Replace every 500 hours of operation or
lint filters
once a year.
Air intake filter
Wash and dry with soap and water every 500
hours of operation or as needed.
Fuel filter
Clean twice a heating season or as needed. See Fuel Filter, page 11.
Fan blades
Clean every season or as needed.
Motor
Not required/permanently lubricated.
160930-01A
measure in this range heater should not be
plugged into generator.
Refer to Operation, page 6, for starting, stop-
ping and resetting heater procedures.
Alternator
Figure 4 - Typical Generator Grounding
Method (Generator construction may
3. Properly dispose of old and dirty fuel.
Check with local automotive service sta-
tions that recycle oil.
4. If storing, store heater in dry place. Make
sure storage place is free of dust and
corrosive fumes.
IMPORTANT: Do not store kerosene over
summer months for use during next heating
season. Using old fuel could damage heater.
www.usaprocom.com
Ground Wire (#10 AWG -
Stranded-Copper)
vary from that shown)
How To
See Storing, Transporting, or
Shipping, above.
See Air Output, Air Intake and
Lint Filters, page 10.
See Air Output, Air Intake and
Lint Filters, page 10.
See Fan, page 10.
Ground Lug
Copper
or Brass
Grounding
Point
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ppk200t

Tabla de contenido