Ash or soot out of the
stove.
Every intervention has be done from qualify staff !
Disconnect the equipment from electrical system before every maintenance operation
Every repairs must be done by our authorized assistance centre.
ALARM SIGNAL ON CONTROL PANEL
Alarm
Explication
In the starting
phase the
lighting of
No
lighting
fuel failed or
fire has not
been noticed
Fume expeller
Fan
motor is
Lightin
breakdown
No fire is
Error
noted in the
Fire
burner basket
− The fire door is open
during combustion.
− No seal between the
combustion fan and
exhaus gas.
Probable cause
No pellets feed
Lighting element broken
Fume feeler has not noticed
fire
Difficulties to light the
pellets
Someting is blocking the
fume motor
Electrical connections
interrupted
Breakdown motor
No pellet feeding
Fume feeler
61/124
IT-GB-FR-ES mod. 501-501X-501L-501LX
− Please to close the fire door when
the stove is lighting.
− To seal every parts of exhaus
system and call the assistance
centre.
− Ignition harness could ne checked
only with apparatus not electrical
connected.
− Reparation has to be done by a
qualify staff.
Cure
Check if there is pellet into the
container
Check operating of screw feeder
Check electrical wiring.
Replace lighting element.
Verify the position, operating and
electrical connection of fume
temperature feeler.
Utilize better quality of pellets
Check fume exhaust duct.
Check electrical connection of the
motor and revolotion counter
(encoder).
Replace motor.
Verify pellet available in container
Verify screw feeder operating
Verify stoppage/clogging screw
feeder.
Verify electrical wire.
Verify the position of fume feeler.
Verify/replace fume feeler.
.