Greenlee CM-1360 Manual De Instrucciones página 13

Medidores con pinza
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Typical Measurements and Accuracy (cont'd)
Current Measurement (cont'd)
AC and DC Clamp
AC Current (CM-1560 and CMI-1000 only)
Range
60.00 A
600.0 A
1000 A
* Maximum crest factor < 1.4:1 at full scale and < 2.8:1 at half scale.
† Induced error for adjacent current carrying conductors is < 0.02 A/A.
AC Current (CM-1360 and CMI-1360 only)
Range
60.00 A
600.0 A
1000 A
* Maximum crest factor < 1.4:1 at full scale and < 2.8:1 at half scale.
† Induced error for adjacent current carrying conductors is < 0.05 A/A.
^ For any measurement, when the conductor is not positioned on the center of the jaws, add 2.0% to the
accuracy for position error.
DC Current (CM-1560 and CMI-1000 only)
Range
60.00 A
600.0 A
1000 A
† Induced error for adjacent current carrying conductors is < 0.02 A/A.
AC + DC Current (CM-1560 and CMI-1000 only)
Range
60.00 A
600.0 A
1000 A
* Maximum crest factor < 1.4:1 at full scale and < 2.8:1 at half scale.
† Induced error for adjacent current carrying conductors is < 0.08 A/A.
Note: Use Δ if there is an offset before the measurement is taken.
Hz
A
Accuracy Range
0.00 A to 8.99 A
9.00 A to 60.00 A
60.0 A to 600.0 A
600 A to 1000 A
Accuracy Range
0.00 A to 5.99 A
6.00 A to 60.00 A
60.0 A to 600.0 A
600 A to 1000 A
Accuracy Range
0.00 A to 8.99 A
9.00 A to 60.00 A
60.0 A to 600.0 A
600 A to 1000 A
Accuracy Range
0.00 A to 8.99 A
4.00 A to 60.00 A
60.0 A to 600.0 A
600 A to 1000 A
CM-1360 • CM-1560 • CMH-1000 • CMI-1000
Accuracy at
40 Hz to 100 Hz*†
± (1.8% + 0.15 A)
± (1.8% + 0.05 A)
± (1.8% + 0.5 A)
± (1.8% + 5 A)
Accuracy at
40 Hz to 100 Hz*†
± (1.8% + 0.15 A)
± (1.8% + 0.05 A)
± (1.8% + 0.5 A)
± (1.8% + 5 A)
Accuracy†
± (1.8% + 0.15 A)
± (1.8% + 0.05 A)
± (1.8% + 0.5 A)
± (1.8% + 5 A)
Accuracy at DC,
40 Hz to 100 Hz*†
± (2.2% + 0.17 A)
± (2.2% + 0.07 A)
± (2.2% + 0.7 A)
± (2.2% + 7 A)
Accuracy at
100 Hz to 400 Hz*†
± (2.2% + 0.15 A)
± (2.2% + 0.05 A)
± (2.2% + 0.5 A)
± (2.2% + 5 A)
Accuracy at
100 Hz to 400 Hz*†^
± (2.2% + 0.15 A)
± (2.2% + 0.05 A)
± (2.2% + 0.5 A)
± (2.2% + 5 A)
Accuracy at
100 Hz to 400 Hz*†
± (2.5% + 0.17 A)
± (2.5% + 0.07 A)
± (2.5% + 0.7 A)
± (2.5% + 7 A)
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cm-1560Cmh-1000Cmi-1000

Tabla de contenido