The illustration below includes cutout dimensions and minimum spacing requirements. The illustration is for reference. The design of
your cabinet layout can be personalized, but the dimensions for the cutouts and minimum spacing must be followed.
Center or support surfaces must be level.
The installation of this grill must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI
Z223.1/NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The grill drops into the opening and is supported by its side flanges. Do not use a bottom support.
11
7/16
" (29.0 cm)
1¾" (4.4 cm)
2½" (6.3 cm)
23
5/8
" (60.0 cm)
14" (35.6 cm)
Built-in Outdoor Grill Enclosure Ventilation Requirements
Any enclosure is to be ventilated by openings at both the top and
lower levels of the enclosure. The following information is the
minimum for proper ventilation of your island construction.
■
There should be a minimum of 1 7/8" (4.4 cm) of clearance
from the bottom of the grease tray and the front wall of the
island for proper ventilation.
NOTE: There should be no solid surface underneath the
firebox portion of the grill.
■
A minimum of 3" (7.6 cm) is required between the back of the
grill and any noncombustible materials. A minimum of
24" (61.0 cm) is required between the back of the grill and any
combustible material.
Cabinet Cutout Dimensions
3" (7.6 cm)
2½" (6.3 cm)
1" (2.5 cm)
25/32
1
" (4.5 cm)
5" (12.7 cm)
2½" (6.3 cm)
2½" (6.3 cm)
12" (30.5 cm)
1½" (3.8 cm)
■
The island must be vented in one of the 2 following ways:
A 90° or a 180° ventilation in the island to ensure that air flows
through the island at either 90° or 180°.
■
Any enclosure for built-in installation is to have at least one
ventilation opening on an exposed exterior side located within
2½" (6.0 cm) of the top and is to be a minimum of
20 in.
2
(129.0 cm
2
1½" (3.0 cm) of the bottom of the enclosure, and the bottom
opening is to be a minimum of 10 in.
openings are to be unobstructed. Every opening is to be a
minimum of 1/8" (0.32 cm) wide.
6" (15.2 cm)
5" (12.7 cm)
2" (5.1 cm)
1" (2.5 cm)
10" (25.4 cm)
). One ventilation opening within
2
(64.5 cm
8
5/8
" (21.9 cm)
3
3/8
" (85.7 cm)
2" (5.1 cm)
2
). All vent
7