DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE
The data plate is on the front of the side (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
CAUTION: hot surface
WARNING: If this radiant heater is positioned adjacent to other areas or appliances, it is
recommended that, within the range of the radiation, these areas or appliances be made of non-
combustible material, otherwise, they shall be clad with a non-combustible heat-insulating material,
and attention is to be paid to fire prevention regulations.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription in force.
The appliance is supplied without the electric connection cable. To install the power supply cable, proceed as follows:
•
Disconnect the power supply.
•
Remove the front panel
•
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
•
Block the cable with the cable blocker, and reassemble the front panel. The earth wire must be longer than the
others so that if the cable blocker should break, it will disconnect after the tension wires.
The appliance must be connected to an equipotential system. The connection screw is positioned at the back of the
appliance and is identified by the
GB
IT
TECHNICAL DATA TABLE
MODELS
230 VAC-1 50/60 Hz
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
EQUIPOTENTIAL
symbol.
IE
CH
BS-94EM
BST-94EM
40x90x29h
40x90x90h
230 VAC-1 50/60 Hz
6,4 A
1,47 kW
1,47 kW
3x1 mm²
3x1 mm²
16
6,4 A