Installation
Installation check codes
Check code
Vent condition is good.
0
The vent is clogged.
Clg (Cg)
About 80 % of the vent is clogged.
C80 (C8)
(This may decrease the drying
performance.)
Over 90 % of the vent is clogged.
C90 (C9)
(This may lead to poor drying
performance or cause malfunction)
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
or too high (over 104 °F (40 °C)) and
Ct
therefore vent blockage cannot be
detected.
Temperature sensor error
tC
Unit is detecting items inside the
drum or there is an error on the dry
C1
sensor.
Unit is detecting door is open
dC
Abnormal voltage detected
9C1
English
28
DV7350N_DC68-03784L-01_EN.indd 28
Meaning
Solution
1. Clean the lint filter.
2. Check your vent condition.
(Refer to the "Ducting
requirements" section)
* You must take measures (such as
cleaning) through expert personnel.
Leave the dryer at room
temperature (41~95 °F (5~35 °C))
for an hour and check again.
Contact a service center.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
Close the door properly and check
again.
If the problem continues, contact a
service center.
Check the power connection. (Refer
to the "Connect the electrical wiring"
section)
If the problem continues, contact a
service center.