Installation
2
Heater Jacket Installation — S19-671HR
Heater Belt
Align the spring clamp from the heater
belt directly below the eyewash yoke
assembly .
A
Make sure the heater belt and
tank are clean and free of debris.
Wrap the belt around the tank four
inches from the bottom of the tank .
Heater jacket
Plug the heat trace cable and
the heater belt power cables
into the Y-cord . Place the plugs
and Y-connection body into the
B
inside pocket of the jacket . Tuck
any excess cable from heaters
inside tank jacket .
Route the three power cords out
of the bottom of the pocket .
Close the zipper on
C
the pocket and lock
closed with screw
and nut provided .
Bradley • 215-1748 Rev. C; ECN 18-05-033
4"
(102mm)
A
Route the power cord out of the bottom
D
of the hook-and-loop slot in the jacket .
Secure the hook and loop strips on the
slot of the jacket . Pull the drawstring
tight at the top of the jacket .
B
Align the pocket on the jacket, just
to the side of the eyewash yoke,
away from the retaining spring on
the heater pad . Slide the jacket up
the outside of the tank .
Loop the heater cable from the
E
yoke assembly around the outside
of the tank handles, tucking the
cable into the top of the heater
jacket .
9/10/2018
S19-671HR
Using a pliers or similar
tool, secure the heater
belt to the tank .
5