Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
ON/OFF
ON/OFF
SWITCH
SWITCH
LINE
LINE
IN
IN
BLACK
BLACK
WHITE
WHITE
ON/OFF
ON/OFF
SWITCH
SWITCH
(purchase separately)
(purchase separately)
Attach cable clamp to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
2
Connect wires
BLK
BLK
BLK
BLK
WHT
WHT
WHT
WHT
GRD
GRD
GRD
GRD
SWITCH BOX
SWITCH BOX
RED
RED
GROUND (green or bare)
GROUND (green or bare)
SWITCH BOX
SWITCH BOX
120 VAC LINE IN
120 VAC LINE IN
BLK
RED
BLK
RED
WHT
WHT
FAN
FAN
UNIT
UNIT
RECEPTACLE
RECEPTACLE
KNOCKOUT
KNOCKOUT
PLATE
PLATE
XB50
XB80
XB110 Installation Guide
n
n
3
4
Screw from
Parts Bag