Descargar Imprimir esta página

Grohe Talia 19 709 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

953881.book : I95388us.fm Seite 1 Dienstag, März 16, 1999 1:10 PM
Application
Pressure Balancing Valves are designed for use with
hot water supplied from pressurized storage heaters
and offer the highest temperature accuracy when used
in this way.
Pressure Balancing Valves cannot be used in
conjunction with low-pressure storage heaters
(displacement water heaters).
Specifications
• Concealed single handle pressure balancing tub
and shower valve
• Integral service stops (35 210 / 35 214)
• Integral check valves prevents cross flow
• Pressure balanced diaphragm cartridge automati-
cally adjusts to inlet pressure fluctuations.
Cartridge restricts hot water supply should the cold
water pressure fail - to prevent scalding.
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Max. test pressure
• Flow rate:
- Outlet
13.5 L/min or 3.5 gpm/20 psi
30.5 L/min or 8 gpm/100 psi
- Shower
29 L/min or 7.6 gpm/100 psi
• Temperature
- max. (hot water inlet)
- maximum temperature is reached when the
handle is rotated 270° in a counterclockwise
direction.
The handle rotation stop may be used to limit the
maximum temperature.
• Back to back installation possible by reversing the
pressure balancing cartridge
• Water connection
1
English
20 psi
20 - 72.5 psi
145 psi
500 psi
20 L/min or 5.2 gpm/45 psi
13 L/min or 3.4 gpm/20 psi
19 L/min or 5 gpm/45 psi
176 °F
hot - LH
cold - RH
Installation
Final installation
1. Remove the two screws (A1) from the fitting
template (A), then remove the template,
see fold-out page I, fig. [1].
2. Make sure the water supply is turned on at the
service stop valves (B). Stop valves must be in
fully open position.
3. Turn the valve stem (C) clockwise to OFF
position, see fig. [2].
4. The adjustable hot water limit stop (D) is factory
set at neutral position to give maximum outlet
temperature.
Please refer to chapter "Maximum hot water
limit setting" on page 2 for limiting maximum
outlet temperature.
5. Push sleeve (E) onto the plastic guide (G) by
gently pressing the slotted section (G1) on the
plastic guide.
6. Slide the escutcheon support (H) over the slee-
ve (E) and tighten with screws (H1), see fig. [3].
Do not use excessive force to tighten the
screws.
7. Grease O-ring (H2) with the grease provided and
slide onto the sleeve (E).
8. Snap escutcheon (J) into escutcheon sup-
port (H).
9. Position the handle (K) so that the cold water
position is on top of the sleeve (E), then tighten
screw (K1) securely, see fig. [4].
10. Push on decorative ring (L) or lever ring.
11. Screw on handle cap (M).
The pressure balancing valve is now ready
for use.
If the pressure balancing valve is installed too
deep, the fitting depth can be increased by 1" with an
extension set, Part No. 47 344, see fold-out page II.

Publicidad

loading

Este manual también es adecuado para:

Talia 19 710