Error Codes; Options Menu; Normal And Eco Mode - AGA marvel MA15C Serie Instrucciones De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Error codes:

The ice machine is monitored continuously. Any OPEN or
SHORTED circuit condition with a temperature sensor or
miscommunications between the control and user interface
will initiate an ERROR CODE as listed below:
Error
"OFF" will flash continuously in 1
Bin Sensor error
second intervals in the display. No
audible alarm will sound.
"ICE" will flash continuously in
System Sensor error
the display. No audible alarm will
Continual flashing of all indicators
Communication error

Options menu:

Normal and ECO mode:

Your ice machine comes with an optional "ECO" mode.
This new feature allows you to tailor ice production to a
conservative rate, saving approximately 25% energy and
30% water from routine operation. While in this mode
ice production will slow and the appliance will use less
water and electricity. "ECO" mode should only
be initiated after there is a full bin of ice. To enter
"ECO" mode do the following:
Press the "MENU" icon twice and the green
"ECO" will flash.
Press and hold the "ON/OFF" icon until the
green "ECO" stops flashing and remains
illuminated.
To return to the standard operating rate press the
"MENU" icon twice, the ECO will turn off and
the "ICE" will be flashing. Press and hold the
"ON/OFF" icon until the "ICE" stops flashing
and remains illuminated.
USING YOUR ELECTRONIC CONTROL
Displayed Code
Failed condenser temperature sensor. Machine operation
will continue but ice production cycle will not adapt to
sound.
varying ambient conditions, so ice quality may vary.
Loss of communication between the main board and the
on the display.
ECO
Error Codes
Error Description
Failed temperature sensor. Machine operation will
immediately enter an OFF state.
user interface.
ICE
16
Action to Take
Call service to have the
temperature sensor replaced.
Call service to have the
temperature sensor replaced.
Call service to have a
diagnostic check.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ml15c serieMo15c serieMp15c serie

Tabla de contenido