ASSEMBLY INSTRUCTIONS
The maximum inlet gas supply pressure: 250 psi /1750 kPa. The minimum inlet gas supply pressure:
5 psi /35kPa.
Place a dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of
dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or
plugs may result in leakage of propane.
DO NOT obstruct the flow of combustion air and ventilation air to the fire pit.
The propane cylinder must be arranged for vapor withdrawal and equipped with a listed overfilling
prevention device. Please use the proper cylinder orientation to provide vapor withdrawal.
NOTE: The cylinder must be fully upright for the cylinder to have vapor withdrawal only.
CORRECT
a. Do not store a spare LP-gas cylinder under or near this appliance.
b. Never fill the cylinder beyond 80 percent full.
c. If the information in (a) and (b) is not followed exactly, a fire causing death or serious injury
may occur.
The pressure regulator and hose assembly supplied with the appliance must be used. The installation
must conform with local codes, or in the absence of local codes, with national fuel gas code, ANS
Z223.1/NFPA54, natural gas and propane Installation Code, CSA B149.1, or propane storage and
handling code, B149.2.
12. Seat and position propane cylinder in the bottom
plate (K).
WRONG
CAUTION
12
15
WRONG
K