Pre-fabricated kit assembly

9.1
9.2
Closed.
9.3
9.4
9.5
9.6
A: green thrust collar
B: white thrust collar
Slide the plastic hose into the thrust collar until there is a noticeable resistance.
9.7
open

10. Function

10.1 1. Start
2. Stop
Automatic according to set flush volume.
10.2 A: flow pressure 1.2 – 4.0 bar
B: 6 – 9 l for each activation
C: 1.0 – 1.3 l/s

11. Adjusting the flush volume

11.1 Remove the cover plate.
11.2 Interrupt the water supply (possible at the isolating valve according to the design).
11.3 Set according to the diagrams.

12. Remove upper section

12.1 Remove the cover plate.
12.2 Interrupt the water supply (possible at the isolating valve according to the design).
12.3 Remove the upper section according to the diagrams.

13. Replacing the plastic hose

13.1 Press the ring in arrow direction.
13.2 Pull out the plastic hose.