The connecting pipe has an external diameter of 78 mm, to which you need a pipe with a diameter of 80 mm.
If the pipe work is further than 1 m, the pipe diameter must be increased to 100 mm and a correspondingly
larger wall valve must be chosen. In warm rooms the channel should be insulated with 30 mm mineral wool
covered with a damp-proof course (plastic). It is important that the lead-in between the pipe and the wall (or
floor) is sealed with jointing compound. You can eventually use the complete Aduro fresh air kit.
The pipe with external supply of combustion air can be taken out at the bottom of the back side of the stove
or under the stove (see illustration below):
If you want to use the wood burning stove without connecting the supply of combustion air, "brake" off the
cover plate in the rear cover at the bottom of the back of the stove.
3.5 Ways of installation
Indirect
through
external wall
Through
wall
Trough floor
and crawl
space
Through
floor and
foundation