Function introduction
(2) Locking/unlocking
The G icon is displayed, indicating that the panel is under locking status. At this time, by pr-
essing the B5 "OK" key and holding it for 3 s, the G icon disappears, such that the panel can
be unlocked. By pressing the B5 "OK" key again and holding it for 3 s, the G icon is displayed
, such that the panel can be locked again.
(3) Refrigerating chamber temperature adjustment (2~8 ) (operation under unlocking status)
After the Menu key is pressed, the set value A icon of the original refrigerating chamber sta-
rts blinking, entering the refrigerating chamber temperature setting mode.
Afterwards, when adjusting the B3 key, the temperature value increases by 1 each time the
B3 is pressed, recycling among 02~08~OF. Press the OK key to determine the selection.
When the refrigerating chamber is set at the OF position, the refrigerating chamber is dea-
ctivated; when it is set at other temperature positions, the refrigerating chamber is activated
and refrigerating. If the key operation is not performed within 5 s or other keys are pressed
during the adjustment, then the set value is not confirmed and is returned to the original set
position.
(4) Freezing chamber temperature adjustment (-16~-24 ) (operation under unlocking status)
Select the freezing temperature settings via the Menu key, the original freezing chamber s-
et temperature icon B starts blinking, entering the freezing chamber temperature setting s-
tatus.
Afterwards, the freezing chamber temperature decreases by 1 each time the B3 is pressed,
recycling between -16~-24. Press the OK key to determine the selection. If the key operat-
ion is not performed within 5 s or other keys are pressed during the adjustment, then the te-
mperature set value is not confirmed and is returned to the original set position.
(5) Timing setting:
1. When dispatched from the factory, the timing region displays "00", the "alarm clock" icon
does not light up, without entering the timing status.
2. Under the unlocking status, by selecting the "Menu" key to select the timing region, the f-
igure "00" blinks. Then, press the "adjust" key to set the timing to "00" ~ "99" ~ "00". By p-
ressing the "adjust" key, the timing increases by 1; by keeping on pressing the "adjust" k-
ey, the timing increases by degrees quickly at a certain speed to the time of completion o-
f the selection. Each time the "timing" key is pressed, the buzzer beeps once. By pressin-
g the "OK" key to confirm the start of countdown, the "alarm clock" icon is displayed.
3. When the countdown goes to "00", the figure "00" blinks , the buzzer alarms and the
"alarm clock" icon extinguishes. The buzzer stops alarming and the figure stops blinking
after the user presses the "Set" key.
4. Special function 1: if time adjustment is required by the user during the countdown, by s-
electing the "Menu" key to select the timing region, the figure blinks, and then by pressing
the "adjust" key, the figure changes and recycles from the currently displayed time to "99"
~"00"~"99", and after the adjustment is done, the countdown starts by pressing the "OK"
key to confirm.
5. Special function 2: if timing is required to be stopped by the user during the countdown,
first by selecting the "Menu" key to select the timing region and pressing the "adjust" key,
the figure blinks and is adjusted to "00" via the "adjust" key, and by pressing the "OK" key
to confirm, the "alarm clock" icon extinguishes to exit the timing function.
All manuals and user guides at all-guides.com