Nedo ECO 600 HV Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Structure
ECO 600 HV control panel
"Move laser in anti-clockwise direction"
1
Press button/keep pressed: Moves the laser dot
incrementally/constantly or the scan array
(limited laser line)
incrementally in an anti-clockwise direction.
"Move laser in clockwise direction" button
Press button/keep pressed: Moves the laser dot
2
incrementally/constantly or the scan array
(limited laser line)
incrementally in a clockwise direction.
"x-axis tilt adjustment" buttons
3
These two buttons can be used in the "manual
levelling" position to set the tilt of the x-axis.
"Scan angle
(limited laser line)" button
Button is only active in "Rotational speed = 0"
4
mode. It consecutively switches the various
scan angles (limited laser line) through:
0° – 6° – 20° – 50° – 90°.
"Rotational speed" button
Successively switches the different rotational
speeds on or off:
5
0 – 60 – 120 – 300 – 600 rpm.
When it is switched on, the laser always rotates
with 600 rpm.
"y-axis tilt adjustment" buttons
6
These two buttons can be used in the "manual
levelling" position to set the tilt of the y-axis.
"Height monitoring" button
This button is used to switch on automatic
7
height monitoring. Following a strong jolt which
results to a change in height, the laser stops
"Height monitoring" LED display
Flashes green if height monitoring is switched
8
The LED flashes quickly if the unit has
identified a change in height due to a strong
ON/OFF button
9
Switches the unit on and off.
"Equipment On" LED display
10
Lights up red if the unit is switched on.
"Levelling" LED display
11
Lights up red if the unit is switched to manual
"Levelling" button
12
Switch between automatic and manual mode.
Operating Instructions ECO 600 HV Rotating Laser
button
rotating.
on.
jolt.
mode.
2
1
12
11
3
9
7
8
10
EN
4
5
6
12

Publicidad

Tabla de contenido
loading

Tabla de contenido