Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technische Daten
Betriebsdruck:
Empfohlener Betriebsdruck:
Prüfdruck:
Heißwassertemperatur:
Empfohlene Heißwassertemperatur:
Durchflussleistung:
Thermische Desinfektion:
Das Produkt ist ausschließlich für Trinkwasser konzipiert!
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with
water heater switched off
Water escaping in area of swivel
spout
Water escaping at the threaded
base
Water escaping bels ow handle
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 5 l/min
max. 70°C / 4 min
Cause
- Spray former calcified, dirty
- Filter at the isolation valves soils.
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Cartridge defective
Assembly (see page 34)
English
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 33)
Maintenance (see page 39)
• The check valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
• When changing the spray former, it is imperative to
use one made for this type of mixer.
Spare parts (see page 40)
Cleaning (see page 41)
Operation (see page 38)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• When the storage tank is being heated, the spout
will drip.
65°C
Test certificate (see page 44)
Remedy
- Clean spray former, exchanging if
necessary
- Clean the filter / exchange filter
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Exchange cartridge