Configuration - Salto UBOX4000 Guia De Instalacion

Tabla de contenido

Publicidad

Configuration:

Eng
1. Prepare the network connection (Ethernet cable). Generate a tamper alarm by opening the CU housing or removing the tamper
switch cable and then press the CLR button to detect all the
connected readers. Check that the readers LEDs are ON (READER 1, READER 2).
2. Perform the set up in the software (Consult SALTO ProAccess SPACE user guide).
assign the IP address to the UBOX4000.
3. Adress the CU42E0:
3.1. Press the CLR BUTTON (CU42E0) to detect the readers. Check that the reader's LEDs blink and the
BUS485 LEDs are switched ON.
3.2. The UBOX4000 is a DHCP ready device. If there's no DCHP server, the user can manually set up a static IP address using a web
browser.
3.2.1. Press the CLR button for 5 seconds to access the addressing mode (LED ON will blink orange).
3.2.2. Access the IP address 192.168.0.234 with your web browser. Set up the network parameters and click on "send".
3.2.3. The UBOX4000 will leave the addressing mode automatically, but you can also leave the addressing mode manually by
pressing the CLR button for 5 seconds.
4. Use SALTO ProAccess software to detect the device (consult SALTO ProAccess Software user manual).
All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
Installation guide
UBOX4000
XS4 Controller
©
2020 SALTO Systems S.L.
226079-ED2.- 12/02/2021
6/18

Publicidad

Tabla de contenido
loading

Tabla de contenido