MAINTENANCE MODE - LCD
Maintenance Mode allows access to service and diagnostic information, as well as provides the ability to adjust certain
program default parameters. To enter Maintenance Mode:
1. Press and hold the
,
2. A beep will sound and "MAINTENANCE MODE" will display momentarily in the Information Window.
3. Release all keys. "SERIAL NO #####" will display in the Information Window.
The following keys are available in MAINTENANCE MODE:
Increase and Decrease LEVEL Keys: Adjust the value of the displayed parameter up and down, respectively, in
incre- ments of 1 unit. These keys do not save the new value - see OK Key below.
Numeric Keypad: Allows you to enter specific values for numeric parameters. These keys do not save the new
value - see OK Key below.
OK Key: Updates (saves) the values of all parameters in non-volatile memory, and exits Maintenance Mode.
NOTE: To exit Maintenance Mode without saving any values or settings, press the QUICK START key.
A complete list of the items that you may display and change in Maintenance Mode:
Item
Vx.xx Sum
Update software
contrast
backlight
WD
pd time
Burn in mode
and
keys together.
Min
Max
N/A
N/A
N/A
N/A
0
100
10
200
N/A
N/A
N/A
N/A
Default
Notes
V958
6C92FBD4
Update console software via USB
100
Display contrast setting
200
Display backlight setting
on/off
on/off
Person Detect
N/A
(Manufacture Only)
26