Electrical connection
WARNING:
These installation instructions are intended for use by qualified installers.
WARNING:
Avoid the risk of an electric shock!
Insert into a grounded receptacle.
Never remove grounding phase.
Do not use any adapters.
Do not use any extension cords.
WARNING:
It is the customer's responsibility to ensure that the appliance installation is in compliance with all national
and local electrical codes and ordinances. Non-compliance with these instructions may result in death,
fire or an electric shock.
The receptacle must be near the appliance, 61" (1550mm) to the right of the appliance or 37" (940mm)
to the left of the appliance, and also freely accessible following installation of the appliance for future
service.
The appliance complies with protection class I. Connect the appliance to 115 V/ 60Hz alternating
current via a correctly installed receptacle with grounded terminal.
The appliance comes with a UL registered 3-wire power cord NEMA 5-15p type. The appliance
requires a 3-pole receptacle.
WARNING:
Never connect the appliance to electronic energy saver plugs.
This appliance can be used with mains and sine-controlled inverters. Main controlled inverters are used
for photovoltaic systems which are connected directly to the national grid.
Sine-controlled inverters must be used for isolated applications (e.g. on ships or in mountain lodges)
which are not connected directly to the national grid.
Never remove the grounding phase