Before performing any cleaning or maintenance operations, disconnect the appli-
ance by unplugging it or using the main switch. The manufacturer disclaims all li-
ability for any damage that may be directly or indirectly caused to people, things and
animals due to the failure to follow all the instructions provided in this booklet and
above all the warnings relating to the installation, operation and maintenance of the
appliance.
- there is a fire risk if cleaning is not carried out in accordance with the instructions.
CAUTION: Accessible parts may become hot when used with cooking appliances.
WARNING: Failure to install the screws or fixing device in accordance with these instruc-
tions may result in electrical hazards.
Warning only for Australia: hood width less than 90 cm: use max. 4 hobs
CAUTION:
This product must be disposed of at end of life according to the rules in force.
B

TECHNICAL SPECIFICATIONS

The technical data pertaining to the electric appliance The technical specifications of the
appliance are shown on the rating plates located inside the range hood.
C
INSTALLATION
(Section reserved for qualified installers of the range hood)
The recommended distance between the cooker and the lower part of the range hood
for the installation is about 110 cm. In borderline cases, with a slight efficiency loss, the
distance can be increased to about 150 cm. The minimum distance cannot be less than 65
cm, as envisioned by the Standard.
Should the instructions of the gas cooker specify a greater distance, take this into consid-
eration.
Assembly instructions: see section "M" of the booklet.
D

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from the
mains power supply.
Check that the wires inside the range hood are not disconnected or cut; if this is the
case, contact your nearest service centre. The electrical connections must be per-
formed by qualified personnel.
The connections must be performed in compliance with the legal standards in force. Check
that the relief valve and the electrical system are able to support the load of the appliance
(see the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case, "standardised"
plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue wire must be used for the neutral,
- the brown wire must be used for the phase; the cable must not come into contact with
hot parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a suitable
16