Front Panel Information
The VI-8 LEDs are as follows (from left to right when viewing the front of the chassis):
1. 24V DC power 1
2. 24V DC power 2
3. Fault
4. Activity
5. Status
6. Audio Channel 1
7. Audio Channel 2
8. Audio Channel 3
9. Audio Channel 4
10. Audio Channel 5
11. Audio Channel 6
12. Audio Channel 7
13. Audio Channel 8
Power (Chassis Indicator)
The VI-8 has two power indicators. If power is applied to one or both 24V DC power connectors, the
corresponding LED will be on.
Off – The power connection is not available or not within the voltage range.
Solid green – The unit is receiving power.
Fault (Chassis Indicator)
There are two types of chassis Faults that will be reported depending on the severity of the problem.
Audio may still be passing, but if the condition causing the warning is not corrected, a failure may occur.
Flashing amber – A Control Input configured as "high range – monitored" input has a Fault.
Solid amber – A chassis Fault is active on the VI-8.
Activity (Chassis Indicator)
The VI-8 has an activity LED that will illuminate to show the configuration status of the unit.
Off – The unit is not configured.
Solid green – The unit is configured.
Status (Chassis Indicator)
The VI-8 has a tri-color Status LED that indicates the health of the hardware.
Solid green – The unit is powered up and working normally.
Flashing amber – Shown during the power-up self-test.
Solid red – The unit experienced a problem during the power-up self-test.
Audio Channel
Green – Audio signal level is between -48 dBFS and -18 dBFS.
Amber – Audio signal level is between -18 dBFS and -3 dBFS.
Red – Audio signal level is above -3dBFS.