Eikon
Arké
20136
19136
Dimmer 230 V~ 50 Hz for: 40-500 W incandescent lamps, 40-300 VA electronic transfomers,
10-200 W CFL lamps, 3-200 W LED lamps and LED electronic transfomers, control with built-in
push button or from NO peripheral push buttons, control and regulation by rotary potentiometer,
MASTER function, minimum power control, visible in darkness, grey. Not for Isoset enclosures.
The solution combined with the Plana residential series is also available in antibacterial
version (art. 14136.AB). The antibacterial treatment ensures full hygiene thanks to the action
of the silver ions (AG+), which prevent the formation and spread of germs, bacteria, viruses
and fungi. To maintain the hygiene and effectiveness of its antibacterial action, clean the
product regularly.
IMPORTANT: Lamps controllable from a single MASTER or SLAVE dimmer must all be
the same. All controllable loads must be declared DIMMERABLE by the manufacturer.
Check the type of compatible dimmering on the lamp package: LE (Leading Edge) or TE
(Trailing Edge). Where not specified, the lamp works in both modes, at the discretion of
the installer; choose the type of dimmering that ensures the best lamp.
Dimmering with Leading Edge mode
CHARACTERISTICS
• Turning on and turning off is with the built-in button or normal buttons without pilot light when
off; knob dimmering.
• Soft start: ensures gradual lighting from zero to maximum or preset lighting levels. This way the
life of a lamp is increased by reducing stress on the filament and prevents light flash.
• Flash start: used with compact fluorescent lamps, ensures that the lamps are switched on
correctly, reducing any difficulties to a minimum.
• Soft end: slowly brings the load down from on to off.
• Leading Edge mode: used with incandescent lamps, compact fluorescent lamps and LED
compatible lamps, as well as L-type electronic transformers
• Tailing Edge mode: used with compatible loads such as fluorescent lamps, LED lamps or
C-type electronic transformers
.
C
• Protection against short-circuit when turning on together with flashing blowout detector.
• Overheating protection with flashing blowout detector.
• MASTER-SLAVE function: paying attention not to exceed maximum power controllable by
each dimmer. A MASTER device can have up to 3 SLAVE devices.
• It should be used in dry, dust-free places at a temperature between 0 °C and +35 °C.
• For installations with 2 dimmers in the same box the loads controllable by each dimmer should
be reduced so that their total does not exceed the values indicated above.
CONNECTIONS
• The connection should be made together with a fuse box with quick-acting fuse with high
breaking capacity type F2,5AH 250 V~ (07050.HF.2).
• Control with built-in button or more points with NO buttons in parallel. Do not use NO buttons
with pilot light.
NOTE: THE ON/OFF BUTTON IS CONNECTED TO THE CABLE NEUTRAL.
• In the 2-wire connection of the adapter load must be positioned as close as possible to the
lamp and connected in parallel to it.
• For correct operation, the length of each connection between the MASTER and SLAVE dim-
mers or the NO buttons may not exceed 100 m.
• Press the connection conductors to the bottom of the box to prevent them from coming into
contact with the dimmer body.
STANDARD COMPLIANCE
BT directive
EMC directive
EN 60669-2-1 standard.
Viale Vicenza, 14 - 36063 Marostica VI - Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188
Fax (Export) +39 0424 488 709
www.vimar.com
Idea
Plana
16603
14136
14136.AB
Dimmering with Trailing Edge mode
.
L
3-WIRE CONNECTION
L
20136-19136
16603-14136
20416
P
19416
16460
14416
L
Button ON/OFF
N
Controllable loads
40 - 500 W
10 - 100 W (max 5 lamps)
3 - 100 W (max 5 lamps)
40 - 300 VA
(max 3 transformers
Power supplies
max 10 power supplies
01874-01875
Lamps 02662
max 10 lamps
2-WIRE CONNECTION
L
20136-19136
16603-14136
20416
19416
16460
14416
L
P
Button ON/OFF
N
Controllable loads
*
10 - 40 W (max 2 lamps)
*
3 - 40 W (max 2 lamps)
*
may need charging adapter 01873 connected in parallel to the lamp.
SETTING
Remove the upper button.
N
LE
TE
40 - 300 W
10 - 200 W (max 10 lamps)
3 - 200 W (max 10 lamps)
40 - 300 VA
)
(max 5 transformers
L
Not applicable
Not applicable
The 2-wire connec-
tion
be used to replace
regulators in existing
electrical
where it is not 'this
the neutral wire in the
box of the dimmer.
LE
TE
40 - 400 W
40 - 200 W
10 - 40 W (max 2 lamps)
3 - 40 W (max 2 lamps)
Increases the
minimum
Decreases the
minimum
Flash start
TE
switch on for max. 1
second then taken to the
set brightness
LE
Soft start
gradually switched on to the
set brightness
)
C
should
only
systems