Installation And Commissioning; Maintenance And Cleaning - Grohe Blue HOME 31 498 Manual Del Usuario

Ocultar thumbs Ver también para Blue HOME 31 498:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
Technical data cooler/carbonator electrical data:
• Connection:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative air humidity:
• Refrigerant:
• Safety shut-off of pump:
• Operating pressure:
Sanitary data:
• Cooler/carbonator cooled water capacity:
• System operating pressure:
• Flow rate at 0.3 MPa flow pressure:
• Ambient temperature:
• Temperature
– Cooler /carbonator water inlet:
– Cooled water temperature:
• Sound pressure level L
A (frestanding):
p
• Adjustable bypass, factory setting:
• Filter capacity at bypass setting 2
(Carbonate hardness 17 - 24 °KH):
• Water connection
– cooler/carbonator:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
The test for electromagnetic compatibility (interference emission test)
was performed at the rated voltage and rated current.
Technical data fitting:
• Flow pressuremin. 0,1 MPa/recommended 0,2 - 0,5 MPa
• Operating pressure:
• Test pressure:
If static pressure exceeds 5 bar, a pressure-reducing valve must be
fitted.
• Flow rate at 3 bar flow pressure:
• Temperature
- Hot water supply:
- Recommended (energy saving):
Water connection:
Thermical disinfektion of the fitting is possible.
Wall socket with earth wire, protected
via a 10 A fuse
230 V AC / 50 Hz
0.025 kg - R600a
approx. 4:30 min
min. 0.2 MPa - max. 1 MPa
max. 0.6 MPa
approx. 2 l/min
approx. 5 – 10 °C
max. 600 liters
corresponds to max. 12 months
max. 1 MPa
approx. 9 l/min
Flush pipes thoroughly before and after installation (observe
EN 806).
180 W
Adjust bypass of filterhead according to local carbonate
IP21
hardness and connect filter cartridge.
max. 75%
The carbonate hardness can be tested by using the enclosed test
strip or the relevant water supplier can provide information on the
carbonate hardness.
The fitting has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
1.4 l
Note: Make sure that the water inlet hose does not come loose
by movement when installing the cooler.
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines. In order to ensure
4 – 32 °C
that the cooling fluid has run back, the cooler/carbonator
may only be installed following a pause of 24 hours.
max. 20 °C
Control:
50 ± 4 dB
The buttons have the following functions:
2
 Filter replacement reset
 Filter size selection and carbontate hardness adjustment
 CO2 reset
Display:
cold - blue
In the inactive state, the remaining filter capacity is displayed in
percent.
When carbonat hardness ≤ 9° the use of activated carbon filter
(Order no.: 40 547 001) is recommended.
A
The cooler/carbonator is set for operation with the S-Size filter
2
cartridge (Prod no.: 40 404 001) at the factory.
2,500 V
For operation with other filter cartridges the cooler/carbonator must be
set out.
Important!
1,6 MPa
Risk of damage!
Always disconnect the power supply and interrupt the CO
supply before carrying out maintenance work on the
system. The plug-in connector can then be disconnected.
Cleaning cooler/carbonator
max. 70 °C
For hygienic and healthy reasons, the cooler/carbonator must
60 °C
be cleaned once a year. Cleaning must be performed before
cold
changing the filter cartridge, in order to prevent contamination
of the replacement filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434 001) and the
accompanying adapter (Prod. no.: 40 694 000 or 40 699 000)
could be ordered at www.shop.grohe.com.

Installation and commissioning

GROHE recommends a depth of min. 510 mm for
the cabinet.

Maintenance and Cleaning

2
20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

31543dc0

Tabla de contenido