5.2 Mechanical connection with bar of several actuators

On very wide openings, it is possible, having checked the force necessary for opening/closing (calculated
according to the table under Section 5.2), to connect in parallel electrical actuators and mechanical spindles
to provide several pushing points and ensure correct and constant opening/closing of the window. It is
advisable to fit an additional pushing point every 1.2 metres (approx.)
Top-hung outward opening window with 2 or more pushing points: type
Carry out the assembly for the pushing points by following the installation sequence in Section 5.1
Top-hung outward opening window with 2 or more pushing points: Accessories to be used
10